Our work

Recent work.

A selection of recent jobs across Newcastle and Lake Macquarie: switchboard and mains upgrades, EV chargers, lighting, renovations, and commercial and industrial work.

Got a similar job? Mention which one when you get in touch and we can usually give you a ballpark on the spot.
Reverse osmosis plant on a concrete slab: stainless membrane housings on a frame with a vertical high-pressure pump in frontCompleted plant
Inside the control panel: circuit breakers, PLC, terminals and two variable speed drives, neatly wiredPanel wiring
Stainless steel control panel door with a touchscreen, drive keypads, indicator lights and an emergency stopControl panel
Vertical multistage pump with its motor cabled in flexible conduit, beside a flow meter on the pipeworkInstruments
Second high-pressure pump and dosing pump wired at the end of the membrane rackPump wiring
Reverse osmosis plant: electrical installation and control panel

An RO (Reverse Osmosis) plant project completed over this past week, including the electrical installation and control panel works.

The work covered power and control cabling to the high-pressure pumps, the flow and pressure instruments and the actuated valves, and a stainless steel control panel with PLC, touchscreen and variable speed drives for the pumps.

Scope
Electrical installation and control panel works
Type
Industrial
Old switchboard with the cover off: mismatched breakers and a tangle of red, white and blue wiringBefore
Same enclosure rebuilt with a neat row of labelled safety switches and the wiring dressed into tidy loopsAfter
Switchboard rebuild

Breakers from three brands, safety switches on only some of the circuits, and untidy wiring. The board was stripped back and rebuilt in the same enclosure: main switch, an RCBO on every circuit, surge protection, every cable re-terminated and a circuit schedule inside the door.

Suburb
Adamstown
Time
One day, power off about four hours
Type
Switchboard upgrade
Café front counter with green pendant lights, downlights and warm LED strip under the benchtopFront counter
Commercial kitchen with LED panel lighting, stainless benches, refrigeration and an exhaust hood over the cooking lineKitchen
Distribution board with a main isolator, a lighting and power chassis of labelled circuit breakers and an emergency lighting warning labelDistribution board
Three rotary isolating switches on the tiled wall beside the cooking equipment, under the exhaust hoodEquipment isolators
Two heat lamps hanging over the timber pass between the kitchen and the counterHeat lamps at the pass
Under-counter wall with a row of double power points and an isolating switch, neatly set outUnder-bench power
Front view of the counter with pendants above, power points in the shelving and LED strip under the stone benchtopCounter lighting
Café and commercial kitchen fit-out

Complete electrical fit-out for a new café and its commercial kitchen, from the distribution board to the last pendant.

A new distribution board with a main isolator, separate lighting and power circuits, and labelled emergency lighting circuits. In the kitchen: isolating switches for the cooking equipment, power for refrigeration and bench equipment, LED panel lighting, and heat lamps over the pass. Front of house: pendants, downlights and LED strip under the counter, with power for the display fridges and counter equipment.

Scope
Distribution board, kitchen and counter power, equipment isolators, lighting and emergency lighting
Type
Commercial fit-out
Living room at night under dim, yellow halogen downlightsBefore
Same living room lit evenly and brightly by new LED downlightsAfter
Halogen to LED: better light, a tenth of the power

Same room, same positions, photographed the same evening. The old 50 W halogens gave a dim, yellow light and heated the ceiling; the new dimmable LEDs light the room evenly and draw about a tenth of the power. Across twenty-two fittings that's a real difference on the bill. Old transformers came out of the roof, and the dimmers were swapped for ones that actually work with LEDs.

Suburb
Merewether
Time
Half a day
Type
Lighting
Living room at dusk with two slim round LED ceiling lights on a timber-battened ceiling, lit shelves and a glowing sideboardFinished
Living room lighting, fewer fittings

The owners wanted the ceiling grid left clean, so instead of a dozen downlights we fitted two slim LED oyster lights on a dimmer, LED strip along the shelves and under the sideboard, and a lamp circuit on the same switch by the door. Warm white throughout.

Suburb
New Lambton
Time
One day
Type
Lighting
Tesla Wall Connector mounted on a rendered wall with its cable coiled and an isolator switch beside itTesla Wall Connector
Sigenergy EV charger on an outside wall beside a garage housing the home battery and inverter22 kW Sigenergy
EV chargers, from a Wall Connector to solar-integrated

We've recently installed a range of EV chargers. Two of them: a Tesla Wall Connector on its own circuit with an isolator beside it, and a 22 kW Sigenergy charger fully integrated with the home's solar and battery system, so the car charges from the roof when the sun is out.

Before we quote any charger we check the switchboard and the supply can carry it.

Suburbs
Merewether and Eleebana
Time
Half a day to a day each
Type
EV chargers
Kitchen mid-renovation with the cabinet carcasses in, pendant cables hanging from the ceiling and wiring poking out of the walls and islandBefore
Finished kitchen with three stone pendants over the island, under-cabinet lighting on and matte black power pointsAfter
Kitchen renovation, rough-in to fit-off

Same spot, rough-in and fit-off. The first photo is after the carcasses went in: pendant cables dropped through the ceiling, wiring left at each outlet and in the island. The second is handover. New circuits for the induction cooktop, oven and dishwasher, power in the island, three pendants on a dimmer, under-cabinet strip, matte black outlets to go with the tapware.

Suburb
Hamilton
Time
Two and a half days across the build
Type
Renovation
Ensuite with two backlit arched mirrors, LED strip glowing under a floating timber vanity and a lit niche in the showerFinished
Ensuite fit-off

The electrical side of an ensuite renovation. Backlit arched mirrors on their own switch, LED strip under the floating vanity, a lit niche in the shower, heated towel rail and underfloor heating circuits, and a quiet exhaust fan on a run-on timer.

Suburb
Kotara
Time
Rough-in and fit-off across the build
Type
Renovation
Weathered old meter box on a weatherboard wall with a crowded switchboard and loose wiring under the meterBefore
New galvanised meter box on the same wall with a new switchboard above a new meter panel, everything labelledAfter
Meter board and consumer mains upgrade

A tired meter box with a crowded board and mains that were never sized for a modern house. We replaced the lot and brought the installation up to date with current regulations.

The new board is neat, organised and labelled, with spare room on it. The house now has the capacity for future electrical upgrades, whether that's an EV charger, an induction cooktop or a battery.

Suburb
Mayfield
Time
One day
Included
New meter board and switchboard, consumer mains upgrade, new protection and circuit breakers throughout
Type
Mains and switchboard
Steel shed with the roller door up, four LED battens lit on the rafters and a workbench along the back wallFinished
New shed, wired from scratch

A sub-main from the house board to a small board in the shed, four LED battens on the rafters so there are no shadows over the bench, a run of power points along the back wall, an outside light over the door and a spare circuit left for a charger or a welder later.

Suburb
Cameron Park
Time
One day
Type
Sheds and garages
Garage workshop lit by long LED battens on the ceiling, with strip lighting under black wall cabinets over the benchFinished
Garage workshop lighting

LED battens across the ceiling in a neutral white so the whole floor is evenly lit, and a strip under the overhead cabinets so the bench itself has no shadows. Two switches: one for the battens at the door, one for the bench. Replaced a single bulb in the middle of the ceiling.

Suburb
Charlestown
Time
Half a day
Type
Lighting
Front entry at dusk with downlights in the porch soffit, an up-and-down wall light beside the door, lit step treads and a path bollardFinished
Front entry lighting

Downlights in the porch soffit, an up-and-down wall light beside the door, LED strip under the step treads so nobody misses the edge, and a bollard along the path. All on a daylight sensor with a timer, so it looks after itself.

Suburb
Merewether
Time
Two days, with the landscaper
Type
Outdoor lighting
Meter box with a row of old plug-in circuit breakers under the meter, wiring exposed and no safety switchesBefore
Same meter box with a new white enclosed switchboard under the meter and a row of labelled safety switchesAfter
Switchboard upgrade with a new main earth

Old plug-in breakers under the meter, live parts exposed and not a safety switch on the board. We made this switchboard safe with all new safety switches, one on every circuit, and brought it up to current standards with a new main earth as well.

Everything now sits in a closed, labelled enclosure in the same meter box.

Suburb
Wallsend
Time
Half a day
Type
Switchboard upgrade
Bedroom with a white ceiling fan with built-in light and LED downlights in the ceilingBedroom
Living room with a white ceiling fan with built-in light and LED downlights in the ceilingLiving room
Ceiling fans and LED downlights

Ceiling fans with built-in LED lights in the bedroom and living room, with new LED downlights around them. Each fan is fixed to the roof framing, and the downlights sit clear of the blades so the light doesn't flicker when the fan is running.

Included
Ceiling fans with lights, LED downlights, switching
Type
Fans and lighting

Got something like one of these?